沙特标准、计量和质量组织(SASO)于2023年11月17日发布的《电磁兼容性技术法规》于2024年5月17日正式执行。
法规旨在规定设备电磁兼容性的标准要求并确定供应商应遵守的合格评定程序,确保产品符合保护用户环境、健康和安全的基本要求,并促进市场监督程序。根据合格评定程序,沙特进口商在Saber平台申请清关证书PCOC和SCOC时,应提供供应商合格声明和EMC测试报告以证明产品满足技术法规。
该技术法规适用于附录Annex I所列的标准定义相关术语的设备(请参考下图法规原文):
Annex I |
||
Sr. |
Title of Standard in English |
Standard No. |
1 |
Rotating electrical machines-Part 1: Rating and performance |
SASO IEC 60034-1 |
2 |
Safety of machinery – Electrical equipment of machines - Part 31: Particular safety and EMC requirements for sewing machines, units and systems |
SASO IEC 60204-31 |
3 |
Measuring relays and protection equipment - Part 26: Electromagnetic compatibility requirement |
SASO GSO IEC 60255-26 |
4 |
Switches for household and similar fixed electrical installations - Part 2-1: Particular requirements – Electronic switches |
SASO IEC 60669-2-1 |
5 |
Automatic electrical controls- Part 1: General requirements |
SASO GSO IEC 60730-1 |
6 |
Automatic electrical controls- Part 2-5: Particular requirements for automatic electrical burner control systems |
SASO GSO IEC 60730-2-5 |
7 |
Automatic electrical controls- Part 2-6: Particular requirements for automatic electrical pressure sensing controls including mechanical requirements |
SASO GSO IEC 60730-2-6 |
8 |
Automatic electrical controls- Part 2-7: Particular requirements for timers and time switches |
SASO GSO IEC 60730-2-7 |
9 |
Automatic electrical controls- Part 2-8: Particular requirements for electrically operated water valves, including mechanical requirements |
SASO GSO IEC 60730-2-8 |
10 |
Automatic electrical controls- Part 2-9: Particular requirements for temperature sensing control |
SASO GSO IEC 60730-2-9 |
11 |
Automatic electrical controls- Part 2-14: Particular requirements for electric actuators |
SASO GSO IEC 60730-2-14 |
12 |
Automatic electrical controls- Part 2-15: Particular requirements for automatic electrical air flow, water flow and water level sensing controls |
SASO GSO IEC 60730-2-15 |
13 |
Telecontrol equipment and systems - Part 2: Operating conditions - Section 1: Power supply and electromagnetic compatibility |
SASO GSO IEC 60870-2-1 |
14 |
Low-voltage switchgear and controlgear - Part 1: General rules |
SASO GSO IEC 60947-1 |
15 |
Low-voltage switchgear and controlgear - Part 2: Circuit- breakers |
SASO GSO IEC 60947-2 |
16 |
low-voltage switchgear and controlgear - Part 3: Switches, disconnectors, switchdisconnectors and fusecombination units |
SASO GSO IEC 60947-3 |
17 |
Low-voltage switchgear and controlgear - Part 4-1: Contactors and motor-starters - Electromechanical contactors and motor starters |
SASO IEC 60947-4-1 |
18 |
Low-voltage switchgear and controlgear - Part 4-2: Contactors and motor-starters – AC semiconductor motor controllers and starters |
SASO IEC 60947-4-2 |
19 |
low-voltage switchgear and controlgear - Part 4-3: Contactors and motor-starters – AC semiconductor controllers and contactors for non-motor loads |
SASO IEC 60947-4-3 |
20 |
Low-voltage switchgear and controlgear - Part 5-1: Control circuit devices and switching elements – Electromechanical control circuit devices |
SASO IEC 60947-5-1 |
21 |
low-voltage switchgear and controlgear - Part 5-2: Control circuit devices and switching elements - Proximity switches |
SASO IEC 60947-5-2 |
22 |
Low-voltage switchgear and controlgear - Part 5-3: Control circuit devices and switching elements - Requirements for proximity devices with defined behaviour under fault conditions (PDDB) |
SASO IEC 60947-5-3 |
23 |
Low-voltage switchgear and controlgear - Part 5-6: Control circuit devices and switching elements - DC interface for proximity sensors and switching amplifiers (NAMUR) |
SASO IEC 60947-5-6 |
24 |
Low-voltage switchgear and controlgear - Part 5-7: Control circuit devices and switching elements - Requirements for proximity devices with analogue output |
SASO IEC 60947-5-7 |
25 |
Low-voltage switchgear and controlgear - Part 5-9: Control circuit devices and switching elements - Flow rate switches |
SASO IEC 60947-5-9 |
26 |
Low-voltage switchgear and controlgear - Part 6-1: Multiple function equipment – Transfer switching equipment |
SASO IEC 60947-6-1 |
27 |
Low-voltage switchgear and controlgear - Part 6-2: Multiple function equipment-Control and protective switching devices (or equipment) (CPS) |
SASO IEC 60947-6-2 |
28 |
Low-voltage switchgear and controlgear - Part 8: Control units for built-in thermal protection (PTC) for rotating electrical machines |
SASO IEC 60947-8 |
29 |
Low-voltage switchgear and controlgear - Part 9-1: Active arc- fault mitigation systems – Arc quenching devices |
IEC 60947-9-1 |
30 |
Arc welding equipment - Part 10: Electromagnetic compatibility (EMC) requirements |
SASO IEC 60974-10 |
31 |
Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current < 16 A per phase) |
SASO GSO IEC 61000-3-2 |
32 |
Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current <= 16 A per phase and not subject to conditional connection |
SASO IEC 61000-3-3 |
33 |
Electromagnetic compatibility (EMC) - Part 3-11: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems - Equipment with rated current <= 75 A and subject to conditional connection |
SASO IEC 61000-3-11 |
34 |
Electromagnetic compatibility (EMC) - Part 3-12: Limits - Limits for harmonic currents produced by equipment connected to public low-voltage systems with input current > 16 A and <=75 A per phase |
SASO IEC 61000-3-12 |
35 |
Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity for residential, commercial and light- industrial environments |
SASO IEC 61000-6-1 |
36 |
Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity for industrial environments |
SASO IEC 61000-6-2 |
37 |
Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for equipment in residential environments |
IEC 61000-6-3 |
38 |
Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments |
SASO IEC 61000-6-4 |
39 |
Electromagnetic compatibility (EMC) - Part 6-5: Generic standards - Immunity for equipment used in power station and substation environment |
SASO IEC 61000-6-5 |
40 |
Residual current operated circuit- breakers without integral overcurrent protection for household and similar uses (RCCBs) - Part 1: General rules |
SASO IEC 61008-1 |
41 |
Residual current operated circuit- breakers with integral overcurrent protection for household and similar uses (RCBOs) - Part 1: General rules |
SASO IEC 61009-1 |
42 |
Switches for appliances - Part 1: General requirements |
SASO IEC 61058-1 |
43 |
Industrial-process measurement and control - Programmable controllers - Part 2: Equipment requirements and tests |
IEC 61131-2 |
44 |
Low-voltage switch mode power supplies - Part 3: Electromagnetic compatibility (EMC) |
SASO IEC 61204-3 |
45 |
Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 1: General requirements |
SASO IEC 61326-1 |
46 |
Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-1: Particular requirements - Test configurations, operational conditions and performance criteria for sensitive test and measurement equipment for EMC unprotected applications |
SASO IEC 61326-2-1 |
47 |
Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-2: Particular requirements - Test configurations, operational conditions and performance criteria for portable test, measuring and monitoring equipment used in low-voltage distribution systems |
SASO IEC 61326-2-2 |
48 |
Electrical equipment for measurement, control and laboratory use- use - EMC requirements - Part 2-3: Particular requirements - Test configuration, operational conditions and performance criteria for transducers with integrated or remote signal conditioning |
SASO IEC 61326-2-3 |
49 |
Low-voltage switchgear and controlgear assemblies - Part 1: General rules |
SASO IEC 61439-1 |
50 |
Low-voltage switchgear and controlgear assemblies - Part 2: Power switchgear and controlgear assemblies |
SASO IEC 61439-2 |
51 |
Low-voltage switchgear and controlgear assemblies - Part 3: Distribution boards intended to be operated by ordinary persons (DBO) |
SASO IEC 61439-3 |
52 |
Low-voltage switchgear and controlgear assemblies - Part 4: Particular requirements for assemblies for construction sites (ACS) |
IEC 61439-4 |
53 |
Low-voltage switchgear and controlgear assemblies - Part 5: Assemblies for power distribution in public networks |
SASO IEC 61439-5 |
54 |
Low-voltage switchgear and controlgear assemblies - Part 6: Busbar trunking systems (busways) |
SASO GSO IEC 61439-6 |
55 |
Residual current-operated protective devices (RCDs) for household and similar use- Electromagnetic compatibility |
SASO IEC 61543 |
56 |
Equipment for general lighting purposes - EMC immunity requirements |
SASO IEC 61547 |
57 |
Electrical safety in low voltage distribution systems up to 1 000 Va.c. and 1 500 V d.c.- Equipment for testing, measuring or monitoring of protective measures - Part 12: Performance measuring and monitoring devices (PMD) |
SASO IEC 61557-12 |
58 |
Electrical accessories - Residual current monitors for household and similar uses (RCMs) |
SASO IEC 62020 |
59 |
Low-voltage switchgear and controlgear-Controller-device interfaces (CDIs) - Part 1: General rules |
SASO IEC 62026-1 |
60 |
Low-voltage switchgear and controlgear-Controller-device interfaces (CDIs) - Part 2: Actuator sensor interface (AS-i) |
SASO IEC 62026-2 |
61 |
Low-voltage switchgear and controlgear-Controller-device interfaces (CDIs) - Part 3: DeviceNet |
SASO IEC 62026-3 |
62 |
Low-voltage switchgear and controlgear-Controller-device interfaces (CDIs) - Part 7: CompoNe |
SASO IEC 62026-7 |
63 |
Uninterruptible power systems (UPS) - Part 2: Electromagnetic compatibility (EMC) requirements |
SASO IEC 62040-2 |
64 |
Electricity metering equipment (a.c.) - General requirements, tests and test conditions - Part 21: Tariff and load control equipment |
SASO IEC 62052-21 |
65 |
Electricity metering equipment (a.c.)- Particular requirements- Part 11: Electromechanical meters for active energy (classes 0,5, 1and 2) |
SASO IEC 62053-11 |
66 |
Electricity metering equipment- Particular requirements - Part 21: Static meters for AC active energy (classes 0,5, 1 and 2) |
IEC 62053-21 |
67 |
Electricity metering equipment- Particular requirements - Part 22: Static meters for AC active energy (classes 0,15, 0,25 and 0,55) |
SASO IEC 62053-22 |
68 |
Electricity metering equipment - Particular requirements - Part 23: Static meters for reactive energy (classes 2 and 3) |
SASO IEC 62053-23 |
69 |
Electricity metering (a.c.)-Tariff and load control - Part 11: Particular requirements for electronic ripple control receivers |
SASO IEC 62054-11 |
70 |
Electricity metering (a.c.) - Tariff and load control - Part 21: Particular requirements for time switches |
SASO IEC 62054-21 |
71 |
Resistance welding equipment - Part 2: Electromagnetic compatibility (EMC) requirements |
SASO IEC 62135-2 |
72 |
Static transfer systems (STS) - Part 2: Electromagnetic compatibility (EMC) requirements |
SASO IEC 62310-2 |
73 |
Type F and type B residual current operated circuit-breakers with and without integral overcurrent protection for household and similar uses |
SASO IEC 62423 |
74 |
Power quality measurement in power supply systems - Part 1: Power quality instruments (PQI) |
SASO IEC 62586-1 |
75 |
Power quality measurement in power supply systems - Part 2: Functional tests and uncertainty requirements |
SASO IEC 62586-2 |
76 |
General requirements for arc fault detection and protection devices (AFDDs) |
SASO IEC 62606 |
77 |
Requirements for automatic reclosing devices (ARDS) for circuit-breakers, RCBOs and RCCBs for household and similar uses |
SASO GSO IEC 63024 |
78 |
Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement |
SASO CISPR 11 |
79 |
Vehicles, boats and internal combustion engines - Radio disturbance characteristics- Limits and methods of measurement for the protection of off-board receivers |
SASO CISPR 12 |
80 |
Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission |
SASO CISPR 14-1 |
81 |
Electromagnetic compatibility- Requirements for household appliances, electric tools and similar apparatus - Part 2: Immunity - Product family standard |
SASO CISPR 14-2 |
82 |
Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment |
SASO CISPR 15 |
83 |
Electromagnetic compatibility of multimedia equipment -Emission requirements |
SASO CISPR 32 |
84 |
Electromechanical elementary relays - Part 1: General and safety requirements |
SASO IEC 61810-1 |
下列设备属于法规豁免范围:
1、无线电设备和电信终端设备
2、航空航天产品及其零部件
3、业余爱好者使用的通讯设备
4、医疗设备
5、具有以下物理特性的设备
不能产生或促成电磁发射的设备,其电磁发射超过允许无线电和电信设备及其他设备按预期工作的水平。
正常使用时不受电磁干扰影响的设备
为专家设计并直接用于研究和开发为目的的电子面板